[Free] 2018(Mar) EnsurePass Braindumps Oracle 1z0-581 Dumps with VCE and PDF 31-40

Ensurepass.com : Ensure you pass the IT Exams
2018 Mar Oracle Official New Released 1z0-581
100% Free Download! 100% Pass Guaranteed!
http://www.EnsurePass.com/1z0-581.html

Pillar Axiom 600 Storage System Certified Implementation Specialist

Question No: 31

Identify the SNMP ports for both queries and traps.

  1. Use port 160 for queries.

  2. Use port 161 for queries.

  3. Use port 162 for queries.

  4. Use port 160 for traps.

  5. Use port 161 for traps.

  6. Use port 162 for traps.

Answer: B,F

Explanation: SNMP uses the default UDP port 161 for general SNMP messages and UDP port 162 for SNMP trap messages.

Question No: 32

When adding a user to the Axiom system, which role should be selected to allow the user to create volumes but not to update the Axiom system itself?

  1. Administrator1

  2. Administrator2

  3. Support

  4. Primary Support

Answer: B

Explanation: Administrator 2:

A login account that has the authority to perform all administrative and configuration tasks, except:

  • Create, modify, or delete administrator accounts and File Servers.

  • Modify systemwide settings such as Simple Network Management Protocol (SNMP).

  • Modify software or hardware configurations.

  • Shut down the system.

Reference: Pillar Axiom Administrator#39;s Guide, Create Administrator Account Dialog

Question No: 33

The storage administrator is configuring an iSCSI host to boot from the SAN. Which

hardware component is required for the iSCSI host?

  1. The iSCSI host can use a NIC card to boot from the SAN.

  2. The iSCSI host must use a ToE card to boot from the SAN.

  3. The iSCSI host must use a NIC card to boot from the SAN.

  4. The iSCSI host can use a ToE card to boot from the SAN.

Answer: D Explanation:

Note: iSCSI host bus adapters (HBAs) are dedicated network interface controllers that do onboard iSCSI processing (called a TCP Offload Engine, or TOE).

Question No: 34

The storage administrator would like to change the load balancing settings for a volume assigned to a host. Which load balancing settings can be used?

  1. Round Robin

  2. Optimized

  3. Static

  4. Most Recently Used

Answer: A,C

Explanation: Load Balancing

Identifies the type of load balancing that the storage area network (SAN) hosts should perform to access Pillar Axiom LUNs.

Valid types:

  • Static

    Indicates load balancing across multiple paths to the configured LUNs.

    The software selects the best available path, and all commands are sent over that path until the path is no longer operational, in which case the failed path fails over to another appropriate path.

  • Roundrobin

    Indicates load balancing across multiple paths to the configured LUNs.

    Commands are sent one by one using the best available paths, which ensures that LUN commands are evenly distributed over any path that is available to access the LUNs.

    Reference: Pillar Axiom Administrator#39;s Guide, Modify Host, Pillar Axiom Path Manager Tab

    Question No: 35

    Select the hardware component that virtualizes the storage pool.

    1. Pilot

    2. Network Interface Module

    3. Slammer

    4. Private Management Interface

    5. Brick

    Answer: C

    Explanation: The Slammer storage controllers virtualize the storage pool for seamless growth of filesystems.

    Question No: 36

    Identify two tasks involved when staging the Axiom update software.

    1. uploading the software package to the pilot

    2. validating the uploaded software package

    3. installing the software update package to a temporary directory

    4. converting the software update to a proper format

    Answer: A,B

    Explanation: A: You can download from the Customer Support portal the latest software

    and

    firmware updates.

    Upload the Software Package

    After downloading a software update package, you can stage it on the Pilot management controller to prepare the system for the software update. You can perform the update immediately or schedule the update for a later time.

    B: Confirm the Upgrade Paths

    You can review the software packages from which you can upgrade the Pillar Axiom system.

    From the Support tab, click Software Modules.

    2 Choose Actions gt; View Upgrade Paths to Staged Package. 3 Review the upgrade path information provided on the screen.

    Note: If the list shows more than one upgrade version, install the earliest software version first, followed by the subsequent versions.

    Reference: Pillar Axiom Administrator#39;s Guide, About Updating the Pillar Axiom Software

    Question No: 37

    The storage administrator has SAN attached cluster hosts A and B to the Axiom system. These hosts need to be assigned the same volumes. What simplifies the storage administrator#39;s task of associating hosts to the volumes?

    1. Host Group

    2. SAN Host

    3. AxiomONE Path Manager

    4. Associate Hosts

    Answer: A

    Explanation: You can easily manage the mapping of a LUN to SAN hosts by assigning the hosts to a specific group. This group is a named, logical collection of SAN hosts.

    You might have SAN hosts that have been registered by the Pillar Axiom Path Manager (APM) application or might have created a host association for various initiators. You can create additional host associations by using existing APM registered or manually created hosts. This activity is useful if you have host clusters, each of which contains many hosts and each host contains a few initiators.

    Reference: Pillar Axiom Administrator#39;s Guide, About Host Groups

    Question No: 38

    The storage administrator is connecting the Axiom to an existing SAN Fabric. Identify the best for connecting to the SAN Fabric.

    1. Slammer Control Unit 0 Ports 0 and 1 connect into one switch.

    2. Slammer Control Unit 1 Ports 0 and 1 connect into one switch.

    3. Slammer Control Unit 0 Port 0 and Control Unit 1 Port 0 connect into one switch.

    4. Slammer Control Unit 0 Port 1 and Control Unit 1 Port 1 connect into one switch.

    5. Slammer Control Unit 0 Port 0 and Control Unit 1 Port 1 connect into one switch.

    Answer: E Explanation:

    Note: Each NAS Slammer has four network data ports. At least one port for each Slammer control unit (CU) must be connected.

    Question No: 39

    The storage administrator realized that the SAN host is mapped to the wrong cluster host. How can the storage administrator correct the volume mappings?

    1. by moving the SAN host to the correct host group

    2. by manually updating each volume mapping

    3. by associating the SAN host

    4. by installing the AxiomONP Path Manager

    Answer: A

    Explanation: You can easily manage the mapping of a LUN to SAN hosts by assigning the hosts to a specific group. This group is a named, logical collection of SAN hosts.

    You might have SAN hosts that have been registered by the Pillar Axiom Path Manager (APM) application or might have created a host association for various initiators. You can create additional host associations by using existing APM registered or manually created hosts. This activity is useful if you have host

    clusters, each of which contains many hosts and each host contains a few initiators.

    Reference: Pillar Axiom Administrator#39;s Guide, About Host Groups

    Question No: 40

    Which report types are available when creating a new scheduled report? Select all that apply.

    1. LUN Performance

    2. SAN Switch Performance

    3. SAN Hosts

    4. System Configuration

    5. Storage Allocation

    6. System Configuration Detail

    Answer: C,D

    Explanation: Select the type of report you want to generate from the Report Type menu. Choose one of:

  • SAN Hosts (C)

  • System Configuration (D)

  • Storage Performance

  • Storage Use

  • Storage Use per Volume

  • System Configuration Summary

Reference: Pillar Axiom Administrator#39;s Guide, Create a Reporting Schedule

100% Ensurepass Free Download!
Download Free Demo:1z0-581 Demo PDF
100% Ensurepass Free Guaranteed!
1z0-581 Dumps

EnsurePass ExamCollection Testking
Lowest Price Guarantee Yes No No
Up-to-Dated Yes No No
Real Questions Yes No No
Explanation Yes No No
PDF VCE Yes No No
Free VCE Simulator Yes No No
Instant Download Yes No No

Leave a Reply

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.